Telemetry
Location in GUI:
Design » Network Settings » Telemetry
Diagram
Section titled “Diagram”Classes
Section titled “Classes”network_settings (catalyst_center)
Section titled “network_settings (catalyst_center)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| telemetry | List | [telemetry] | No |
telemetry (catalyst_center.network_settings)
Section titled “telemetry (catalyst_center.network_settings)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| name | String | Yes | ||
| wired_data_collection | Boolean | true, false | Yes | true |
| wireless_telemetry | Boolean | true, false | Yes | false |
| enable_netflow_collector_on_devices | Boolean | true, false | Yes | false |
| catalyst_center_as_network_collector | Boolean | true, false | Yes | true |
| netflow_collector_ip_address | IP | No | ||
| netflow_collector_port | Integer | min: 1, max: 65535 | No | |
| snmp_servers | List | IP | No | |
| syslog_servers | List | IP | No | |
| catalyst_center_as_snmp_server | Boolean | true, false | Yes | true |
| catalyst_center_as_syslog_server | Boolean | true, false | Yes | true |
Telemetry settings configure network monitoring and analytics data collection from managed devices, including wired and wireless data collection, SNMP traps, syslog, and NetFlow. Telemetry can use Catalyst Center itself or external collectors. Settings are assigned to sites and inherited down the hierarchy. Applicable to both SDA fabric and non-fabric deployments.
Examples
Section titled “Examples”Example 1: Basic telemetry configuration enabling wired data collection and using Catalyst Center as the primary collector for network monitoring and analytics:
catalyst_center: network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: trueExample 2: Enterprise telemetry setup with comprehensive monitoring including both wired and wireless data collection, NetFlow enabled, and external SNMP and syslog servers for centralized logging and monitoring:
catalyst_center: network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 10.100.5.10 - 10.100.5.11 syslog_servers: - 10.100.5.20 - 10.100.5.21Example 3: Comprehensive global telemetry deployment with multiple configurations for different monitoring requirements including dedicated NetFlow collectors, mixed internal and external monitoring servers, and region-specific telemetry settings for worldwide enterprise infrastructure:
catalyst_center: network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21Example 4: Site assignment configuration demonstrating how to apply different telemetry settings based on site type, monitoring requirements, and infrastructure complexity:
catalyst_center: sites: areas: - name: Corporate Region parent_name: Global/Americas network_settings: telemetry: GLOBAL_COMPREHENSIVE_TELEMETRY - name: Branch Regions parent_name: Global/Americas/Branches network_settings: telemetry: BRANCH_BASIC_TELEMETRY buildings: - name: Corporate Headquarters parent_name: Global/Americas/USA/California/San Jose network_settings: telemetry: ENTERPRISE_TELEMETRY - name: Data Center parent_name: Global/Americas/USA/Texas/Dallas network_settings: telemetry: DC_ADVANCED_TELEMETRY - name: Branch Office parent_name: Global/Americas/USA/Florida/Miami network_settings: telemetry: BASIC_TELEMETRYLocation in GUI:
Design » Network Settings » Telemetry
Diagram
Section titled “Diagram”Classes
Section titled “Classes”network_settings (catalyst_center)
Section titled “network_settings (catalyst_center)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| telemetry | List | [telemetry] | No |
telemetry (catalyst_center.network_settings)
Section titled “telemetry (catalyst_center.network_settings)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| name | String | Yes | ||
| wired_data_collection | Boolean | true, false | Yes | true |
| wireless_telemetry | Boolean | true, false | Yes | false |
| enable_netflow_collector_on_devices | Boolean | true, false | Yes | false |
| catalyst_center_as_network_collector | Boolean | true, false | Yes | true |
| netflow_collector_ip_address | IP | No | ||
| netflow_collector_port | Integer | min: 1, max: 65535 | No | |
| snmp_servers | List | IP | No | |
| syslog_servers | List | IP | No | |
| catalyst_center_as_snmp_server | Boolean | true, false | Yes | true |
| catalyst_center_as_syslog_server | Boolean | true, false | Yes | true |
Examples
Section titled “Examples”Example 1: Basic telemetry configuration enabling wired data collection and using Catalyst Center as the primary collector for network monitoring and analytics:
catalyst_center: network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: trueExample 2: Enterprise telemetry setup with comprehensive monitoring including both wired and wireless data collection, NetFlow enabled, and external SNMP and syslog servers for centralized logging and monitoring:
catalyst_center: network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 10.100.5.10 - 10.100.5.11 syslog_servers: - 10.100.5.20 - 10.100.5.21Example 3: Comprehensive global telemetry deployment with multiple configurations for different monitoring requirements including dedicated NetFlow collectors, mixed internal and external monitoring servers, and region-specific telemetry settings for worldwide enterprise infrastructure:
catalyst_center: network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21Example 4: Site assignment configuration demonstrating how to apply different telemetry settings based on site type, monitoring requirements, and infrastructure complexity:
catalyst_center: sites: areas: - name: Corporate Region parent_name: Global/Americas network_settings: telemetry: GLOBAL_COMPREHENSIVE_TELEMETRY - name: Branch Regions parent_name: Global/Americas/Branches network_settings: telemetry: BRANCH_BASIC_TELEMETRY buildings: - name: Corporate Headquarters parent_name: Global/Americas/USA/California/San Jose network_settings: telemetry: ENTERPRISE_TELEMETRY - name: Data Center parent_name: Global/Americas/USA/Texas/Dallas network_settings: telemetry: DC_ADVANCED_TELEMETRY - name: Branch Office parent_name: Global/Americas/USA/Florida/Miami network_settings: telemetry: BASIC_TELEMETRYLocation in GUI:
Design » Network Settings » Telemetry
Diagram
Section titled “Diagram”Classes
Section titled “Classes”network_settings (catalyst_center)
Section titled “network_settings (catalyst_center)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| telemetry | List | [telemetry] | No |
telemetry (catalyst_center.network_settings)
Section titled “telemetry (catalyst_center.network_settings)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| name | String | Yes | ||
| wired_data_collection | Boolean | true, false | Yes | true |
| wireless_telemetry | Boolean | true, false | Yes | false |
| enable_netflow_collector_on_devices | Boolean | true, false | Yes | false |
| catalyst_center_as_network_collector | Boolean | true, false | Yes | true |
| netflow_collector_ip_address | IP | No | ||
| netflow_collector_port | Integer | min: 1, max: 65535 | No | |
| snmp_servers | List | IP | No | |
| syslog_servers | List | IP | No | |
| catalyst_center_as_snmp_server | Boolean | true, false | Yes | true |
| catalyst_center_as_syslog_server | Boolean | true, false | Yes | true |
Examples
Section titled “Examples”Example 1: Basic telemetry configuration enabling wired data collection and using Catalyst Center as the primary collector for network monitoring and analytics:
catalyst_center: network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: trueExample 2: Enterprise telemetry setup with comprehensive monitoring including both wired and wireless data collection, NetFlow enabled, and external SNMP and syslog servers for centralized logging and monitoring:
catalyst_center: network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 10.100.5.10 - 10.100.5.11 syslog_servers: - 10.100.5.20 - 10.100.5.21Example 3: Comprehensive global telemetry deployment with multiple configurations for different monitoring requirements including dedicated NetFlow collectors, mixed internal and external monitoring servers, and region-specific telemetry settings for worldwide enterprise infrastructure:
catalyst_center: network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21Example 4: Site assignment configuration demonstrating how to apply different telemetry settings based on site type, monitoring requirements, and infrastructure complexity:
catalyst_center: sites: areas: - name: Corporate Region parent_name: Global/Americas network_settings: telemetry: GLOBAL_COMPREHENSIVE_TELEMETRY - name: Branch Regions parent_name: Global/Americas/Branches network_settings: telemetry: BRANCH_BASIC_TELEMETRY buildings: - name: Corporate Headquarters parent_name: Global/Americas/USA/California/San Jose network_settings: telemetry: ENTERPRISE_TELEMETRY - name: Data Center parent_name: Global/Americas/USA/Texas/Dallas network_settings: telemetry: DC_ADVANCED_TELEMETRY - name: Branch Office parent_name: Global/Americas/USA/Florida/Miami network_settings: telemetry: BASIC_TELEMETRYLocation in GUI:
Design » Network Settings » Telemetry
Diagram
Section titled “Diagram”Classes
Section titled “Classes”network_settings (catalyst_center)
Section titled “network_settings (catalyst_center)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| telemetry | List | [telemetry] | No |
telemetry (catalyst_center.network_settings)
Section titled “telemetry (catalyst_center.network_settings)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| name | String | Yes | ||
| wired_data_collection | Boolean | true, false | Yes | true |
| wireless_telemetry | Boolean | true, false | Yes | false |
| enable_netflow_collector_on_devices | Boolean | true, false | Yes | false |
| catalyst_center_as_network_collector | Boolean | true, false | Yes | true |
| netflow_collector_ip_address | IP | No | ||
| netflow_collector_port | Integer | min: 1, max: 65535 | No | |
| snmp_servers | List | IP | No | |
| syslog_servers | List | IP | No | |
| catalyst_center_as_snmp_server | Boolean | true, false | Yes | true |
| catalyst_center_as_syslog_server | Boolean | true, false | Yes | true |
Examples
Section titled “Examples”Example 1: Basic telemetry configuration enabling wired data collection and using Catalyst Center as the primary collector for network monitoring and analytics:
catalyst_center: network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: trueExample 2: Enterprise telemetry setup with comprehensive monitoring including both wired and wireless data collection, NetFlow enabled, and external SNMP and syslog servers for centralized logging and monitoring:
catalyst_center: network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 10.100.5.10 - 10.100.5.11 syslog_servers: - 10.100.5.20 - 10.100.5.21Example 3: Comprehensive global telemetry deployment with multiple configurations for different monitoring requirements including dedicated NetFlow collectors, mixed internal and external monitoring servers, and region-specific telemetry settings for worldwide enterprise infrastructure:
catalyst_center: network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21Example 4: Site assignment configuration demonstrating how to apply different telemetry settings based on site type, monitoring requirements, and infrastructure complexity:
catalyst_center: sites: areas: - name: Corporate Region parent_name: Global/Americas network_settings: telemetry: GLOBAL_COMPREHENSIVE_TELEMETRY - name: Branch Regions parent_name: Global/Americas/Branches network_settings: telemetry: BRANCH_BASIC_TELEMETRY buildings: - name: Corporate Headquarters parent_name: Global/Americas/USA/California/San Jose network_settings: telemetry: ENTERPRISE_TELEMETRY - name: Data Center parent_name: Global/Americas/USA/Texas/Dallas network_settings: telemetry: DC_ADVANCED_TELEMETRY - name: Branch Office parent_name: Global/Americas/USA/Florida/Miami network_settings: telemetry: BASIC_TELEMETRY