Telemetry
Catalyst CenterLocation in GUI:
Design » Network Settings » Telemetry
Diagram
Section titled “Diagram”Diagram
Section titled “Diagram”Classes
Section titled “Classes”catalyst_center
Section titled “catalyst_center”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| sites | Class | sites | No |
catalyst_center
Section titled “catalyst_center”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| network_ | Class | network_ | No |
sites (catalyst_center)
Section titled “sites (catalyst_center)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| global | Class | global | No |
global (catalyst_center.sites)
Section titled “global (catalyst_center.sites)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| network_ | Class | network_ | No |
network_settings (catalyst_center.sites.global)
Section titled “network_settings (catalyst_center.sites.global)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| telemetry | List | telemetry | No |
telemetry (catalyst_center.sites.global.network_settings)
Section titled “telemetry (catalyst_center.sites.global.network_settings)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| name | String | Yes | ||
| wired_ | Boolean | true, false | No | true |
| wireless_ | Boolean | true, false | No | false |
| enable_ | Boolean | true, false | No | false |
| catalyst_ | Boolean | true, false | No | true |
| netflow_ | IP | No | ||
| netflow_ | Integer | min: 1, max: 65535 | No | |
| snmp_servers | List | IP | No | |
| syslog_servers | List | IP | No | |
| catalyst_ | Boolean | true, false | No | true |
| catalyst_ | Boolean | true, false | No | true |
network_settings (catalyst_center)
Section titled “network_settings (catalyst_center)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| telemetry | List | telemetry | No |
telemetry (catalyst_center.network_settings)
Section titled “telemetry (catalyst_center.network_settings)”| Name | Type | Constraint | Mandatory | Default Value |
|---|---|---|---|---|
| name | String | Yes | ||
| wired_ | Boolean | true, false | Yes | true |
| wireless_ | Boolean | true, false | Yes | false |
| enable_ | Boolean | true, false | Yes | false |
| catalyst_ | Boolean | true, false | Yes | true |
| netflow_ | IP | No | ||
| netflow_ | Integer | min: 1, max: 65535 | No | |
| snmp_servers | List | IP | No | |
| syslog_servers | List | IP | No | |
| catalyst_ | Boolean | true, false | Yes | true |
| catalyst_ | Boolean | true, false | Yes | true |
Telemetry settings configure network monitoring and analytics data collection from managed devices, including wired and wireless data collection, SNMP traps, syslog, and NetFlow. Telemetry can use Catalyst Center itself or external collectors. Settings are assigned to sites and inherited down the hierarchy. Applicable to both SDA fabric and non-fabric deployments.
Note: Wired data collection (
wired_data_collection) cannot be disabled on a site that is, or contains, a fabric site. Catalyst Center rejects it withNCND01235: Wired client device tracking setting cannot be disabled as there are one or more fabric site(s) in this hierarchy.Keepwired_data_collection: trueon every telemetry setting that applies to a fabric site or one of its parent sites. On Catalyst Center 3.2.2 the setting must also be enabled before the fabric site is created (NCSO20572).
Note: Catalyst Center does not store a child site setting whose value equals the value inherited from the parent at the time it is written. Such a setting then follows later changes of the parent. For example, if a region sets
wireless_telemetry: falsewhile Global is alsofalse, and Global is later changed totrue, the region showstrueas well. The next plan shows the difference, so after changing a parent site’s telemetry, run a second plan / apply to write the child setting again.
Examples
Section titled “Examples”Example-1: Basic Telemetry with Wired Data Collection
Section titled “Example-1: Basic Telemetry with Wired Data Collection”Basic telemetry configuration enabling wired data collection and using Catalyst Center as the primary collector for network monitoring and analytics.
catalyst_center: sites: global: network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: trueExample-2: Telemetry with Wired, Wireless, NetFlow, and External Servers
Section titled “Example-2: Telemetry with Wired, Wireless, NetFlow, and External Servers”Enterprise telemetry setup with comprehensive monitoring including both wired and wireless data collection, NetFlow enabled, and external SNMP and syslog servers for centralized logging and monitoring.
catalyst_center: sites: global: network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 10.100.5.10 - 10.100.5.11 syslog_servers: - 10.100.5.20 - 10.100.5.21Example-3: Global Telemetry with Multiple Regional Configurations
Section titled “Example-3: Global Telemetry with Multiple Regional Configurations”Comprehensive global telemetry deployment with multiple configurations for different monitoring requirements, including dedicated NetFlow collectors, mixed internal and external monitoring servers, and region-specific telemetry settings.
catalyst_center: sites: areas: - name: GLOBAL_COMPREHENSIVE_TELEMETRY network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: BRANCH_BASIC_TELEMETRY network_settings: telemetry: - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: DC_ADVANCED_TELEMETRY network_settings: telemetry: - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21Example-4: Telemetry Settings Assigned to Specific Sites
Section titled “Example-4: Telemetry Settings Assigned to Specific Sites”Site assignment configuration demonstrating how to apply different telemetry settings based on site type, monitoring requirements, and infrastructure complexity.
catalyst_center: sites: areas: - name: Americas areas: - name: Corporate Region network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: Branches areas: - name: Branch Regions network_settings: telemetry: - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: USA areas: - name: California areas: - name: San Jose buildings: - name: Corporate Headquarters network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 country: United States - name: Texas areas: - name: Dallas buildings: - name: Data Center network_settings: telemetry: - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21 country: United States - name: Florida areas: - name: Miami buildings: - name: Branch Office network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 country: United StatesTelemetry settings configure network monitoring and analytics data collection from managed devices, including wired and wireless data collection, SNMP traps, syslog, and NetFlow. Telemetry can use Catalyst Center itself or external collectors. Settings are assigned to sites and inherited down the hierarchy. Applicable to both SDA fabric and non-fabric deployments.
Examples
Section titled “Examples”Example-1: Basic Telemetry with Wired Data Collection
Section titled “Example-1: Basic Telemetry with Wired Data Collection”Basic telemetry configuration enabling wired data collection and using Catalyst Center as the primary collector for network monitoring and analytics.
catalyst_center: network_settings: telemetry: - name: BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: trueExample-2: Telemetry with Wired, Wireless, NetFlow, and External Servers
Section titled “Example-2: Telemetry with Wired, Wireless, NetFlow, and External Servers”Enterprise telemetry setup with comprehensive monitoring including both wired and wireless data collection, NetFlow enabled, and external SNMP and syslog servers for centralized logging and monitoring.
catalyst_center: network_settings: telemetry: - name: ENTERPRISE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 10.100.5.10 - 10.100.5.11 syslog_servers: - 10.100.5.20 - 10.100.5.21Example-3: Global Telemetry with Multiple Regional Configurations
Section titled “Example-3: Global Telemetry with Multiple Regional Configurations”Comprehensive global telemetry deployment with multiple configurations for different monitoring requirements, including dedicated NetFlow collectors, mixed internal and external monitoring servers, and region-specific telemetry settings.
catalyst_center: network_settings: telemetry: - name: GLOBAL_COMPREHENSIVE_TELEMETRY wired_data_collection: true wireless_telemetry: true enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.100.50 netflow_collector_port: 9995 catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true snmp_servers: - 172.16.100.10 - 172.16.100.11 - 172.16.100.12 syslog_servers: - 172.16.100.20 - 172.16.100.21 - 172.16.100.22 - name: BRANCH_BASIC_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: false catalyst_center_as_network_collector: true catalyst_center_as_snmp_server: true catalyst_center_as_syslog_server: true syslog_servers: - 172.16.200.10 - name: DC_ADVANCED_TELEMETRY wired_data_collection: true wireless_telemetry: false enable_netflow_collector_on_devices: true catalyst_center_as_network_collector: false netflow_collector_ip_address: 172.16.150.100 netflow_collector_port: 2055 catalyst_center_as_snmp_server: false catalyst_center_as_syslog_server: false snmp_servers: - 172.16.150.10 - 172.16.150.11 syslog_servers: - 172.16.150.20 - 172.16.150.21Example-4: Telemetry Settings Assigned to Specific Sites
Section titled “Example-4: Telemetry Settings Assigned to Specific Sites”Site assignment configuration demonstrating how to apply different telemetry settings based on site type, monitoring requirements, and infrastructure complexity.
catalyst_center: sites: areas: - name: Corporate Region parent_name: Global/Americas network_settings: telemetry: GLOBAL_COMPREHENSIVE_TELEMETRY - name: Branch Regions parent_name: Global/Americas/Branches network_settings: telemetry: BRANCH_BASIC_TELEMETRY buildings: - name: Corporate Headquarters parent_name: Global/Americas/USA/California/San Jose network_settings: telemetry: ENTERPRISE_TELEMETRY - name: Data Center parent_name: Global/Americas/USA/Texas/Dallas network_settings: telemetry: DC_ADVANCED_TELEMETRY - name: Branch Office parent_name: Global/Americas/USA/Florida/Miami network_settings: telemetry: BASIC_TELEMETRY