A Switch Control Policy configures Fabric Interconnect-level settings including Ethernet and FC switching modes, MAC address aging, VLAN port count optimization, reserved VLAN range, and UDLD global settings. It is assigned to domain profiles or domain templates.
Location in Intersight GUI :
Policies » Switch Control
Name Type Constraint Mandatory Default Value intersight Class intersight No
Name Type Constraint Mandatory Default Value organizations List organizations No
Name Type Constraint Mandatory Default Value policies Class policies No
Name Type Constraint Mandatory Default Value switch_control List switch_control No
Name Type Constraint Mandatory Default Value name String Regex: ^[a-zA-Z0-9_ . :-] {1, 64}$ Yes description String No managed Boolean true, falseNo truetags List tags No switching_ mode_ ethernet Choice end-host, switchNo end-hostswitching_ mode_ fc Choice end-host, switchNo end-hostjumbo_frame Boolean true, falseNo truevlan_ port_ count_ optimization Boolean true, falseNo falsefabric_ port_ channel_ vhba_ reset Boolean true, falseNo falsereserved_ vlan_ start_ id Integer min: 2, max: 3915 No 3915mac_ address_ table_ aging Choice Default, Custom, NeverNo Defaultmac_aging_time Integer min: 10, max: 918000 No 14500udld_ message_ interval Integer min: 1, max: 90 No 15udld_ recovery_ action Choice none, resetNo none
Name Type Constraint Mandatory Default Value key String Yes value String No type Choice KeyValue, PathTagNo
Example-1: Configure a switch control policy with default end-host switching modes and custom MAC aging, with environment tags.
- name : MySwitchControlPolicy
switching_mode_ethernet : end-host
switching_mode_fc : end-host
mac_address_table_aging : Custom
Example-2: Configure a switch control policy with VLAN port count optimization enabled and UDLD recovery set to reset.
- name : MyOptimizedSwitchPolicy
vlan_port_count_optimization : true
reserved_vlan_start_id : 3915
udld_message_interval : 15
udld_recovery_action : reset